Page 4 Installation Instructions: AM-650 1/4" Streaming Tape Drive
PDI-00650-00, Rev. A00
Setting the SCSI ID
Each SCSI device attached to the SCSI bus must be set to a unique address. Two SCSI devices cannot
share the same address. The AM-650 is a Wide SCSI-2 device, and can therefore be set to any SCSI ID
from 0 through 15 (except 7, which is reserved for the SCSI controller). On the narrow SCSI bus
supported on AMOS computers prior to the AM-6000 (and optionally on the AM-6000), you can use
only IDs 0 through 6. Figure 1 shows the jumper settings for each SCSI ID.
If you have an AM-650 on a Roadrunner 030/040 or an Eagle other than the Super Eagle, and
you want to be able to warm boot from it, it must be set to a higher SCSI ID than any other tape
device on the SCSI bus.
SCSI BUS TERMINATION
To function properly, the SCSI bus on your computer must be terminated at each end. The SCSI
controller terminates one end of the bus; the opposite end of the bus can be terminated in one of two
ways: 1) using the preferred method—an external terminator, or 2) installing on-board terminators in the
peripheral that's
at the other end of the SCSI cable
. You should use method 2 only if, for some reason,
you cannot use an external terminator.
External SCSI Bus Termination
The preferred way to terminate the SCSI bus in an AMOS computer is to install an external terminator.
Using an external terminator makes it easier to install an add-on subsystem (like a portable CD-ROM
drive), eliminating the need to remove terminators from a SCSI device inside the computer.
The AM-650 is very sensitive to termination issues. Any computer with an AM-650 installed
requires active termination
of the SCSI bus. Currently (September 1997), only AM-6000 and
Roadrunner 060 computers include an active terminator as standard equipment; other AMOS
computers come with a passive terminator. If your computer has a passive terminator, replace it
with an active one before using the AM-650. Many active terminators say “active” somewhere
on their housing.
External active terminators are available from Alpha Micro under part numbers PRA-00222-20
(wide active terminator) and PRA-00222-21 (narrow active terminator).
To use the external terminator, you need to insure none of the SCSI devices inside the computer are
terminated. You also need to follow the guidelines in the section on providing termination power to the
SCSI bus, below.
10 and 21-slot rack mount VME computers have no external SCSI connector. To install an external
terminator, you need a special adapter cable, DWB-10200-01. The connector on this cable is compatible
with the external terminator and also allows you to easily attach a portable CD-ROM drive or other SCSI
device.
Figure 2 shows both narrow and wide SCSI terminators: